SDS and HCI comparison & reviews

Summary
Rank
4th 5th 4th
Score
0%
0%
User Reviews
Question?
Not Enabled Not Enabled Not Enabled
Analysis expand by Herman Rutten by Herman Rutten by Herman Rutten
Select All
General expand
0%
0%
0%
  • Fully Supported
  • Limitation
  • Not Supported
  • Information Only
Pros
  • + Extensive platform support
  • + Extensive data protection capabilities
  • + Flexible deployment options
  • + Extensive data protection integration
  • + Policy-based management
  • + Fast streamlined deployment
  • + Flexible architecture
  • + Broad range of hardware support
  • + Built for performance
Cons
  • - No native data integrity verification
  • - Dedup/compr not performance optimized
  • - Disk/node failure protection not capacity optimized
  • - Single server hardware support
  • - No bare-metal support
  • - No native file services
  • - Limited data protection capabilities
  • - No stretched clustering
  • - No dedup capabilities
  Content  
  •  
Content Creator
  Assessment  
  •  
Overview
Name: SANsymphony
Type: Software-only (SDS)
Development Start: 1998
First Product Release: 1999
NEW
Name: HPE SimpliVity 380
Type: Hardware+Software (HCI)
Development Start: 2009
First Product Release: 2013
Name: PowerFlex
Type: Software-only (SDS)
Development Start: Early 2011
First Product Release: dec 2012
NEW
  •  
Maturity
GA Release Dates:
SSY 10.0 PSP12: jan 2021
SSY 10.0 PSP11: aug 2020
SSY 10.0 PSP10: dec 2019
SSY 10.0 PSP9: jul 2019
SSY 10.0 PSP8: sep 2018
SSY 10.0 PSP7: dec 2017
SSY 10.0 PSP6 U5: aug 2017
.
SSY 10.0: jun 2014
SSY 9.0: jul 2012
SSY 8.1: aug 2011
SSY 8.0: dec 2010
SSY 7.0: apr 2009
.
SSY 3.0: 1999
NEW
GA Release Dates:
OmniStack 4.0.1 U1: dec 2020
OmniStack 4.0.1: apr 2020
OmniStack 4.0.0: jan 2020
OmniStack 3.7.10: sep 2019
OmniStack 3.7.9: jun 2019
OmniStack 3.7.8: mar 2019
OmniStack 3.7.7: dec 2018
OmniStack 3.7.6 U1: oct 2018
OmniStack 3.7.6: sep 2018
OmniStack 3.7.5: jul 2018
OmniStack 3.7.4: may 2018
OmniStack 3.7.3: mar 2018
OmniStack 3.7.2: dec 2017
OmniStack 3.7.1: oct 2017
OmniStack 3.7.0: jun 2017
OmniStack 3.6.2: mar 2017
OmniStack 3.6.1: jan 2017
OmniStack 3.5.3: nov 2016
OmniStack 3.5.2: juli 2016
OmniStack 3.5.1: may 2016
OmniStack 3.0.7: aug 2015
OmniStack 2.1.0: jan 2014
OmniStack 1.1.0: aug 2013
NEW
GA Release Dates:
PowerFlex 3.5: jun 2020
VxFlex OS 3.0.1.1: jan 2020
VxFlex OS 3.0.1: sep 2019
VxFlex OS 3.0: mar 2019
VxFlex OS 2.6.1.1: jan 2019
VxFlex OS 2.6.1: oct 2018
VxFlex OS 2.6: may 2018
VxFlex OS 2.5: feb 2018
VxFlex OS 2.0.1.4: oct 2017
VxFlex OS 2.0.1.3: mar 2017
VxFlex OS 2.0: mar 2016
VxFlex OS 1.32: may 2015
VxFlex OS 1.31: dec 2014
VxFlex OS 1.30: sep 2014
VxFlex OS 1.20: oct 2013
VxFlex OS 1.10: dec 2012
NEW
  Pricing  
  •  
Hardware Pricing Model
N/A
N/A
  •  
Software Pricing Model
Capacity based (per TB)
NEW
Per Node (all-inclusive)
Add-ons: RapidDR (per VM)
Per TB
  •  
Support Pricing Model
Capacity based (per TB)
Per Node
Per TB
Design & Deploy expand
0%
0%
0%
  Design  
  •  
Consolidation Scope
Storage
Data Protection
Management
Automation&Orchestration
Compute
Storage
Data Protection (full)
Management
Automation&Orchestration (DR)
Compute
Storage
  •  
Network Topology
1, 10, 25, 40, 100 GbE (iSCSI)
8, 16, 32, 64 Gbps (FC)
1, 10, 25 GbE
1, 10, 25, 40, 100 GbE
  •  
Overall Design Complexity
Medium
Low
High
  •  
External Performance Validation
SPC (Jun 2016)
ESG Lab (Jan 2016)
ESG Lab (jul 2017)
Login VSI (dec 2018; jun 2017)
ESG Lab (oct 2016)
  •  
Evaluation Methods
Free Trial (30-days)
Proof-of-Concept (PoC; up to 12 months)
Cloud Technology Showcase (CTS)
Proof-of-Concept (POC)
Free Download (forever)
Proof-of-Concept (PoC)
  Deploy  
  •  
Deployment Architecture
Single-Layer
Dual-Layer
Single-Layer
Single-Layer
Dual-Layer
  •  
Deployment Method
BYOS (some automation)
Turnkey (very fast; highly automated)
BYOS (some automation)
Workload Support expand
0%
0%
0%
  Virtualization  
  •  
Hypervisor Deployment
Virtual Storage Controller
Kernel (Optional for Hyper-V)
Virtual Storage Controller
vSphere: Virtual Storage Controller + kernel module
Hyper-V/KVM: OS Drivers and packages
  •  
Hypervisor Compatibility
VMware vSphere ESXi 5.5-7.0U1
Microsoft Hyper-V 2012R2/2016/2019
Linux KVM
Citrix Hypervisor 7.1.2/7.6/8.0 (XenServer)
VMware vSphere ESXi 6.5U2-6.7U3
Microsoft Hyper-V 2016 UR6-UR8
VMware vSphere ESXi 6.5-6.7U3*
Microsoft Hyper-V 2012R2/2016/2019**
Citrix Hypervisor 7.1.2/7.6/8.0./8.1 (XenServer)
NEW
  •  
Hypervisor Interconnect
iSCSI
FC
NFS
SMB
PowerFlex
  Bare Metal  
  •  
Bare Metal Compatibility
Microsoft Windows Server 2012R2/2016/2019
Red Hat Enterprise Linux (RHEL) 6.5/6.6/7.3
SUSE Linux Enterprise Server 11.0SP3+4/12.0SP1
Ubuntu Linux 16.04 LTS
CentOS 6.5/6.6/7.3
Oracle Solaris 10.0/11.1/11.2/11.3
N/A
Microsoft Windows Server
Linux Distributions
IBM AIX
NEW
  •  
Bare Metal Interconnect
N/A
Block Device Driver
  Containers  
  •  
Container Integration Type
Built-in (native)
N/A
Built-in (native)
  •  
Container Platform Compatibility
Docker CE/EE 18.03+
Docker CE 17.06.1+ for Linux on ESXi 6.0+
Docker EE/Docker for Windows 17.06+ on ESXi 6.0+
Docker EE 1.12+
Mesos
  •  
Container Platform Interconnect
Docker Volume plugin (certified)
Docker Volume Plugin (certified) + VMware VIB
Docker Volume Plugin (certified)
  •  
Container Host Compatibility
Virtualized container hosts on all supported hypervisors
Bare Metal container hosts
Virtualized container hosts on VMware vSphere hypervisor
Virtualized container hosts on all supported hypervisors
Bare Metal container hosts
  •  
Container Host OS Compatbility
Linux
Linux
Windows 10 or 2016
CentOS
CoreOS
Debian
Red Hat
Ubuntu
  •  
Container Orch. Compatibility
Kubernetes 1.6.5+ on ESXi 6.0+
  •  
Container Orch. Interconnect
Kubernetes CSI plugin
Kubernetes Volume Plugin
PowerFlex-CSI Plugin
  VDI  
  •  
VDI Compatibility
VMware Horizon
Citrix XenDesktop
VMware Horizon
Citrix XenDesktop (certified)
Workspot VDI
VMware Horizon
Citrix XenDesktop
  •  
VDI Load Bearing
VMware: 110 virtual desktops/node
Citrix: 110 virtual desktops/node
VMware: up to 190 virtual desktops/node
Citrix: up to 190 virtual desktops/node
Workspot: up to 150 virtual desktops/node
VMware: unknown
Citrix:unknown
Server Support expand
0%
0%
0%
  Server/Node  
  •  
Hardware Vendor Choice
Many
HPE
Many
  •  
Models
Many
7 models
Many
  •  
Density
1, 2 or 4 nodes per chassis
1 node per chassis
1, 2 or 4 nodes per chassis
  •  
Mixing Allowed
Yes
Partial
Yes
  Components  
  •  
CPU Config
Flexible
Flexible
Flexible
  •  
Memory Config
Flexible
Flexible
  •  
Storage Config
Flexible
Fixed: number of disks + capacity
Flexible
  •  
Network Config
Flexible
Flexible: additional 1, 10, 25 Gbps
Flexible
  •  
GPU Config
NVIDIA Tesla
AMD FirePro
Intel Iris Pro
NVIDIA Tesla (vSphere only)
NVIDIA Tesla
AMD FirePro
Intel Iris Pro
  Scaling  
  •  
Scale-up
CPU
Memory
Storage
GPU
CPU
Memory
Storage
Network
GPU
CPU
Memory
Storage
GPU
  •  
Scale-out
Storage+Compute
Compute-only
Storage-only
Compute+storage
Compute-only (NFS; vSphere)
Compute+storage
Compute-only (SDC)
Storage-only
  •  
Scalability
1-64 nodes in 1-node increments
vSphere: 1-16 storage nodes (cluster); 2-8 storage nodes (stretched cluster); 1-96 storage nodes (Federation) in 1-node increments
Hyper-V: 4 storage nodes (cluster); 2-16 storage nodes (Federation)
3-512 storage nodes in 1-node increments
  •  
Small-scale (ROBO)
2 Node minimum
1 Node minimum (2 Nodes for local HA)
3 Node minimum
Storage Support expand
0%
0%
0%
  General  
  •  
Layout
Block Storage Pool
Parallel File System
on top of Object Store
Block Pool
  •  
Data Locality
Partial
Full
None
  •  
Storage Type(s)
Direct-attached (Raw)
Direct-attached (VoV)
SAN or NAS
Direct-attached (RAID)
Direct-attached (Raw, RAID, File)
  •  
Composition
Magnetic-only
All-Flash
3D XPoint
Hybrid (3D Xpoint and/or Flash and/or Magnetic)
NEW
Hybrid (Flash+Magnetic)
All-Flash (SSD-only)
Magnetic-Only
Hybrid
All-Flash
  •  
Hypervisor OS Layer
SD, USB, DOM, SSD/HDD
SSD
SD, USB or DOM
  Memory  
  •  
Memory Layer
DRAM
NVRAM (PCIe card)
DRAM (VSC)
  •  
Memory Purpose
Read/Write Cache
NVRAM (PCIe): Write Buffer
DRAM (VSC): Read Cache
Read Cache
  •  
Memory Capacity
Up to 8 TB
NVRAM (PCIe): Unknown
DRAM (VSC): 16-48GB for Read Cache
Configurable
  Flash  
  •  
Flash Layer
SSD, PCIe, UltraDIMM, NVMe
SSD, PCIe, UltraDIMM, NVMe
  •  
Flash Purpose
Persistent Storage
All-Flash: Metadata + Persistent Storage Tier
Read Cache
Write Buffer (Flash Storage Pools)
Storage Tier
  •  
Flash Capacity
No limit, up to 1 PB per device
All-Flash: 5-12 SSDs per node
0 - 64 devices per node
  Magnetic  
  •  
Magnetic Layer
SAS or SATA
Hybrid: SATA
SAS or SATA
  •  
Magnetic Purpose
Persistent Storage
Write Buffer (HDD Storage Pools)
Storage Tier
  •  
Magnetic Capacity
No limit, up to 1 PB (per device)
8 SATA HDDs per host/node
0 - 64 devices per node
Data Availability expand
0%
0%
0%
  Reads/Writes  
  •  
Persistent Write Buffer
DRAM (mirrored)
NVRAM (PCIe card)
Flash/HDD
  •  
Disk Failure Protection
2-way and 3-way Mirroring (RAID-1) + opt. Hardware RAID
1 Replica (2N)
+ Hardware RAID (5, 6 or 60)
1 Replica (2N)
+ opt. Hardware RAID
  •  
Node Failure Protection
2-way and 3-way Mirroring (RAID-1)
1 Replica (2N)
+ Hardware RAID (5, 6 or 60)
1 Replica (2N)
+ opt. Hardware RAID
  •  
Block Failure Protection
Not relevant (usually 1-node appliances)
Manual configuration (optional)
Not relevant (1-node chassis only)
Fault Sets
  •  
Rack Failure Protection
Manual configuration
Group Placement
Fault Sets
  •  
Protection Capacity Overhead
Mirroring (2N) (primary): 100%
Mirroring (3N) (primary): 200%
+ Hardware RAID5/6 overhead (optional)
Replica (2N) + RAID5: 125-133%
Replica (2N) + RAID6: 120-133%
Replica (2N) + RAID60: 125-140%
Replica (2N): 100% + Hardware RAID overhead (optional)
  •  
Data Corruption Detection
N/A (hardware dependent)
Read integrity checks (CLI)
Disk scrubbing (software)
Disk scrubbing (software)
In-flight integrity checks
Persistent integrity checks
NEW
  Points-in-Time  
  •  
Snapshot Type
Built-in (native)
Built-in (native)
NEW
  •  
Snapshot Scope
Local + Remote
Local + Remote
  •  
Snapshot Frequency
1 Minute
GUI: 10 minutes (Policy-based)
CLI: 1 minute
1 minute
  •  
Snapshot Granularity
Per VM (Vvols) or Volume
Per VM (Vvols) or Volume
NEW
  •  
Backup Type
Built-in (native)
Built-in (native)
External
  •  
Backup Scope
Local or Remote
Locally
To other SimpliVity sites
To Service Providers
N/A
  •  
Backup Frequency
Continuously
GUI: 10 minutes (Policy-based)
CLI: 1 minute
N/A
  •  
Backup Consistency
Crash Consistent
File System Consistent (Windows)
Application Consistent (MS Apps on Windows)
vSphere: File System Consistent (Windows), Application Consistent (MS Apps on Windows)
Hyper-V: File System Consistent (Windows)
N/A
  •  
Restore Granularity
Entire VM or Volume
vSphere: Entire VM or Single File
Hyper-V: Entire VM
N/A
  •  
Restore Ease-of-use
Entire VM or Volume: GUI
Single File: Multi-step
Entire VM: GUI, CLI and API
Single File: GUI
N/A
  Disaster Recovery  
  •  
Remote Replication Type
Built-in (native)
Built-in (native)
Built-in (native)
NEW
  •  
Remote Replication Scope
To remote sites
To MS Azure Cloud
To remote sites
NEW
  •  
Remote Replication Cloud Function
Data repository
N/A
  •  
Remote Replication Topologies
Single-site and multi-site
Single-site and multi-site
Single-site
NEW
  •  
Remote Replication Frequency
Continuous (near-synchronous)
GUI: 10 minutes (Asynchronous)
CLI: 1 minute (Asynchronous)
Continuous (Stretched Cluster)
30 seconds (Asynchronous)
NEW
  •  
Remote Replication Granularity
VM or Volume
VM (Vvols) or Volume
NEW
  •  
Consistency Groups
Yes
No
Yes
NEW
  •  
DR Orchestration
VMware SRM (certified)
RapidDR (native; VMware only)
NEW
N/A
NEW
  •  
Stretched Cluster (SC)
VMware vSphere: Yes (certified)
VMware vSphere: Yes (certified)
Microsoft Hyper-V: No
N/A
  •  
SC Configuration
2+sites = two or more active sites, 0/1 or more tie-breakers
3-sites: two active sites + tie-breaker in 3rd site (optional)
N/A
  •  
SC Distance
<=5ms RTT (targeted, not required)
<=5ms RTT
N/A
  •  
SC Scaling
<=32 hosts at each active site (per cluster)
<=8 hosts at each active site
N/A
  •  
SC Data Redundancy
Replicas: 1N-2N at each active site
Replicas: 1N at each active site
+ Hardware RAID (5, 6 or 60)
N/A
Data Services expand
0%
0%
0%
  Efficiency  
  •  
Dedup/Compr. Engine
Software (integration)
NEW
Hardware (PCIe)
Software (Limited)
  •  
Dedup/Compr. Function
Efficiency (space savings)
Efficiency and Performance
Efficiency
  •  
Dedup/Compr. Process
Deduplication: Inline (post-ack)
Compression: Inline (post-ack)
Deduplication/Compression: Post-Processing (post process)
NEW
Deduplication: Inline (on-ack)
Compression: Inline (on-ack)
Deduplication: N/A
Compression: inline (post-ack)
  •  
Dedup/Compr. Type
Optional
NEW
Always-on
Optional
  •  
Dedup/Compr. Scope
Persistent data layer
All data (memory-, flash- and persistent data layers)
Persistent Storage
  •  
Dedup/Compr. Radius
Pool (post-processing deduplication domain)
Node (inline deduplication domain)
NEW
Federation
Volume
  •  
Dedup/Compr. Granularity
4-128 KB variable block size (inline)
32-128 KB variable block size (post-processing)
NEW
4-8 KB variable block size
4 KB fixed block size
  •  
Dedup/Compr. Guarantee
N/A
90% (10:1) capacity savings across storage and backup combined
N/A
  •  
Data Rebalancing
Full (optional)
Partial
Full
  •  
Data Tiering
Yes
N/A
N/A
  Performance  
  •  
Task Offloading
vSphere: VMware VAAI-Block (full)
Hyper-V: Microsoft ODX; Space Reclamation (T10 SCSI UNMAP)
vSphere: VMware VAAI-NAS (Limited)
GUI integrated tasks/commands
vSphere: VMware VAAI-Block (partial)
  •  
QoS Type
IOPs and/or MBps Limits
N/A
IOPs and/or MBps Limits (maximums)
  •  
QoS Granularity
Virtual Disk Groups and/or Host Groups
N/A
Per client and volume
  •  
Flash Pinning
Per VM/Virtual Disk/Volume
Not relevant (All-Flash only)
Per Volume
  Security  
  •  
Data Encryption Type
Built-in (native)
N/A
  •  
Data Encryption Options
Hardware: Self-encrypting drives (SEDs)
Software: SANsymphony Encryption
Hardware: Smart array controller
Software: HyTrust DataControl (validated); Vormetric VTE (validated)
Hardware: Self-encrypting drives (SEDs)
Software: Dell EMC CloudLink
NEW
  •  
Data Encryption Scope
Hardware: Data-at-rest
Software: Data-at-rest
Hardware: Data-at-rest
Software: Data-at-rest + Data-in-transit
Hardware: Data-at-rest
Software: Data-at-rest
  •  
Data Encryption Compliance
Hardware: FIPS 140-2 Level 2 (SEDs)
Software: FIPS 140-2 Level 1 (SANsymphony)
Hardware: FIPS 140-2 Level 1 (Smart array controller)
Software: FIPS 140-2 Level 1 (HyTrust, VTE)
Hardware: FIPS 140-2 Level 2 (SEDs)
Software: FIPS 140-2 Level 1 (Dell EMC CloudLink)
  •  
Data Encryption Efficiency Impact
Hardware: No
Software: No
Hardware: No
Software: Yes
Hardware: No
Software: No
  Test/Dev  
  •  
Fast VM Cloning
Yes
Yes
  Portability  
  •  
Hypervisor Migration
Hyper-V to ESXi (external)
ESXi to Hyper-V (external)
Hyper-V to ESXi (external)
ESXi to Hyper-V (external)
Hyper-V to ESXi (external)
ESXi to Hyper-V (external)
  File Services  
  •  
Fileserver Type
Built-in (native)
N/A
N/A
  •  
Fileserver Compatibility
Windows clients
Linux clients
N/A
N/A
  •  
Fileserver Interconnect
SMB
NFS
N/A
N/A
  •  
Fileserver Quotas
Share Quotas, User Quotas
N/A
N/A
  •  
Fileserver Analytics
Partial
N/A
N/A
  Object Services  
  •  
Object Storage Type
N/A
N/A
N/A
  •  
Object Storage Protection
N/A
N/A
N/A
  •  
Object Storage LT Retention
N/A
N/A
N/A
Management expand
0%
0%
0%
  Interfaces  
  •  
GUI Functionality
Centralized
Centralized
Centralized
NEW
  •  
GUI Scope
Single-site and Multi-site
Single-site and Multi-site
Single-system
  •  
GUI Perf. Monitoring
Advanced
Advanced
Basic
  •  
GUI Integration
VMware vSphere Web Client (plugin)
VMware vCenter plug-in for SANsymphony
SCVMM DataCore Storage Management Provider
Microsoft System Center Monitoring Pack
VMware vSphere HTML5 Client (plugin)
SCVMM 2016/2019 (add-in)
VMware vSphere Web Client (plugin)
NEW
  Programmability  
  •  
Policies
Full
Partial (Protection)
Partial
  •  
API/Scripting
REST-APIs
PowerShell
REST-APIs
XML-APIs
PowerShell (community supported)
CLI
REST-APIs
PowerShell
sCLI
  •  
Integration
OpenStack
VMware vRealize Automation (vRA)
Cisco UCS Director
OpenStack
EMC ViPR Controller + ViPR vRealize Orchestrator Plug-in
  •  
Self Service
Full
N/A
N/A (not part of PowerFlex license)
  Maintenance  
  •  
SW Composition
Unified
Unified
Partially Distributed
  •  
SW Upgrade Execution
Rolling Upgrade (1-by-1)
Rolling Upgrade (1-by-1)
Rolling Upgrade (1-by-1)
  •  
FW Upgrade Execution
Hardware dependent
Rolling Upgrade (1-by-1)
Hardware dependent
  Support  
  •  
Single HW/SW Support
No
Yes
No
  •  
Call-Home Function
Partial (HW dependent)
Full
Partial (HW dependent)
  •  
Predictive Analytics
Partial
Full

Matrix Score

  •  
  •  
  • Dell EMC
  • HPE
  • Dell EMC
  •  
  • 4 th
  • 5 th
  • 4 th
X
Login to access your personal profile

Forgot your Password?
X
Signup with linkedin
X

Registered, but not activated? click here (resend activation link)

Login to access your personal profile

Receive new comparison alerts

Show me as community member

I agree to your Terms of services

GDPR